mahucon inner banner

Project D.N. Oxypark Building.

mahucon project image
Bhubaneswer,Odisha

  1. Executing 600mm dia. up to a depth of 20m from ground level with all equipments and materials.
  2.  Conduction Initial Vertical Pile Load test at 2.5 times of stated capacity (i.e. 400MT test load) on the pile by fixing and leveling M.S. bearing plate in position, placement of kentledge of approved capacity and arrangements, fixing of hydraulic jack, datum bars, pressure and dial gauges complete in all respect.